0.6/1 kV
YJV 0.6/1 kV power cable
XLPE (cross-linked polyethylene) · Unarmoured (steel-tape variant → YJV22)
17 rows · IEC 60502-1 · GB/T 12706.1-2008
PREVIEW Specimen partner desk · not for procurement
Cert numbers, entity registration & project references are placeholders pending counterpart sign-off. Verifiable PDFs ship under NDA on first qualified RFQ. · PRATINJAU — bukan untuk pengadaan resmi.
Engineering documentation
Nine cable families, eighty-plus rows of conductor-class-aware spec data, four MV voltage tiers (6/10 → 26/35 kV) with IEC 60502-2 screen design, and eight type-test reports from CESI / DNV KEMA / TÜV Rheinland. Drop the row into your single-line diagram review.
Sample row · YJV22 MV
| Size | Class | OD | Weight | Air 30°C | Buried | Rdc20 | Rac90 | X | Isc 1 s |
|---|---|---|---|---|---|---|---|---|---|
| YJV22 3×185 mm² (12/20 kV) | Class 2 stranded | Ø 74.8 mm ± 1.0 | 8,068 kg/km | 404 A | 380 A | 0.0991 Ω/km | 0.127 Ω/km | 0.108 Ω/km | 26.5 kA |
XLPE 5.5 mm + inner/outer semi-con 0.6 mm + 25 mm² copper-tape screen · PD ≤ 10 pC at 2 U₀ · GB/T 12706.4-2008 / IEC 60502-2. Bend radius 15 × OD = 1,122 mm. Buried at 0.7 m, soil ρ = 2.5 K·m/W. Methods E / D / B2 per IEC 60364-5-52.
Spec matrix · 9 families
0.6/1 kV
XLPE (cross-linked polyethylene) · Unarmoured (steel-tape variant → YJV22)
17 rows · IEC 60502-1 · GB/T 12706.1-2008
0.6/1 kV (LV) · 6/10 kV (MV)
XLPE · Galvanized steel-tape (STA) double-layer overlap
19 rows · IEC 60502-1 · IEC 60502-2
450/750 V
PVC TI1 · Not applicable
12 rows · IEC 60227-3 · GB/T 5023.3
450/750 V
PVC TI1 cores · Not applicable
8 rows · IEC 60227-4 · GB/T 5023.4
300/500 V
PVC TI2 cores · Not applicable
9 rows · IEC 60227-5 · GB/T 5023.5
450/750 V
Double-layer irradiated cross-linked halogen-free low-smoke compound · Not applicable
7 rows · JG/T 441-2014 · IEC 60332-3
450/750 V
PVC or XLPE (per family) · Shield (KVVRP) · steel-tape (KVV22) · plain (KVV)
9 rows · GB/T 9330.1-2020 · GB/T 9330.2-2020
Data (PoE+ supported on Cat6 with bundling derating)
Polyethylene (PE) per pair · Optional foil/braid shield (F/UTP / SF/UTP)
3 rows · TIA/EIA-568-C.2 · ISO/IEC 11801
0.6/1 kV
XLPE · Optional steel-tape; molded-joint factory pre-cast
4 rows · JB/T 10743-2007 · Project drawing schedule required
IEC type-test reports
The lab + standard + scope per report below is fixed; the report number, issue date, and signed PDF release on issuance under NDA at first qualified RFQ. The verify-portal links below open the lab's public lookup surface for buyer cross-reference on the issued number.
IEC 60502-1 (2004) + A1 (2009)
Type tests on YJV 0.6/1 kV XLPE-insulated power cable: tensile strength, elongation, thermal aging, hot-set, water absorption, AC voltage 3.5 kV / 5 min, partial discharge, bending + tan δ, heating cycle.
IEC 60502-2 (2014)
Type tests on YJV22 6/10 kV three-core armoured cable: partial discharge ≤ 10 pC at 2 U₀, AC voltage 6.5 kV (U₀) for 5 min, impulse withstand 95 kV peak, screen system continuity, 8-hour heat cycle, water absorption.
IEC 60228 (2004)
Conductor resistance verification — Class 1 solid, Class 2 stranded, Class 5 flexible compliance for sections 1.5 → 240 mm². Resistance measured at 20 °C and corrected to 20 °C ambient.
IEC 60331-1-2 (2018)
Fire-resistance test at 750 °C for 180 minutes with mechanical impact at 5 min intervals. Circuit continuity verified across the full burn cycle on 4×2.5 mm² sample.
IEC 60332-3-24 (Category C)
Flame propagation test on bunched cables (Category C — bundled 1.5 L/m of non-metallic material): no flame propagation beyond 2.5 m above burner after 20 minutes burner application.
IEC 61034-2 (2019)
Smoke density on burning cable: minimum 60 % light transmittance under steady-state burn conditions, 3 m cube test chamber, measurement at 0.6 m height.
IEC 60754-1 (2019)
Determination of halogen acid gas (HCl + HBr) content of materials taken from the cable insulation and sheath: result < 5 mg/g (LSZH compound compliance).
IEC 60754-2 (2019)
Determination of degree of acidity (pH) and conductivity of combustion gases from cable materials: pH ≥ 4.3 and conductivity ≤ 10 μS/mm.
IEC 60502-2 (2014)
Type tests on YJV22 12/20 kV three-core armoured cable: partial discharge ≤ 10 pC at 2 U₀, AC voltage 21 kV (U₀) for 5 min, impulse withstand 125 kV peak, screen system continuity, 8-hour heat cycle, water absorption. Pending coordinated re-test against the 6/10 kV specimen entry.
Trust posture
Construction stack
Outer sheath, insulation, conductor, shield or armor — buyer-readable layers.
Order package
Coils, 305 m boxes, drums, end caps, and handling cues.
Route risk
Buried runs, tunnels, trays, control cabinets, risers tied to family selection.
Document gate
Certificate wording, test reports, payee, model coverage stay verified before order.
Next page
See commercial terms, channel split, wholesale FOB, Indonesia readiness.